DOE Occupational Radiation Exposure: 2006 Annual Report
Exhibit B-6b. Distribution of TEDE by Facility Type - 2005.
Total Effective Dose Equivalent (TEDE) Number of Individuals Receiving Radiation Doses in Each Dose Range (rem) |
||||||||||||||||
| Facility Type | Less than Meas. | Meas. 0-0.10 | 0.10-0.25 | 0.25-0.50 | 0.50-0.75 | 0.75-1.00 | 1-2 | 2-3 | 3-4 | 4-5 | >5 | Total Monitored | Percent of Monitored with Meas. TEDE |
No. with Meas. TEDE |
Collective TEDE (person-rem) |
Avg. Meas. TEDE (rem) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Accelerator | 11,050 | 1,204 | 87 | 22 | 3 | 12,366 |
11% |
1,316 |
51.298 |
0.039 |
||||||
| Fuel/Uran. Enrich. | 475 | 106 | 581 |
18% |
106 |
1.985 |
0.019 |
|||||||||
| Fuel Fabrication | 872 | 716 | 87 | 36 | 7 | 1,718 |
49% |
846 |
48.829 |
0.058 |
||||||
| Fuel Processing | 1,112 | 485 | 67 | 23 | 3 | 1,690 |
34% |
578 |
35.307 |
0.061 |
||||||
| Maint. and Support | 11,409 | 1,750 | 334 | 142 | 51 | 15 | 3 | 13,704 |
17% |
2,295 |
193.899 |
0.084 |
||||
| Other | 11,452 | 1,908 | 282 | 177 | 38 | 9 | 3 | 1 | 13,870 |
17% |
2,418 |
194.786 |
0.081 |
|||
| Reactor | 148 | 43 | 8 | 10 | 209 |
29% |
61 |
6.038 |
0.099 |
|||||||
| Research, General | 29,473 | 2,084 | 274 | 96 | 25 | 13 | 8 | 31,973 |
8% |
2,500 |
169.528 |
0.068 |
||||
| Research, Fusion | 264 | 149 | 1 | 1 | 415 |
36% |
151 |
1.988 |
0.013 |
|||||||
| Waste Proc./ Mgmt. | 5,526 | 2,197 | 372 | 74 | 3 | 8,172 |
32% |
2,646 |
146.265 |
0.055 |
||||||
| Weapons Fab. & Test | 10,124 | 2,895 | 240 | 63 | 11 | 5 | 4 | 13,342 |
24% |
3,218 |
139.058 |
0.043 |
||||
| Totals | 81,905 | 13,537 | 1,752 | 644 | 141 | 42 | 18 | 1 | 98,040 |
16% |
16,135 |
988.981 |
0.061 |
|||
Note: Arrowed values indicate the greatest value in each column.