| DOE Occupational Radiation Exposure: 2010 Annual Report Exhibit B-9. Distribution of TED by Facility Type Listed in Descending Order of Average Measurable TED for Fuel Facilities, 2010. |
||||||||||||||||||||||
| FUEL FACILITIES |
||||||||||||||||||||||
| Number of Individuals Receiving Radiation Doses in Each Dose Range (rem) | ||||||||||||||||||||||
| Site/Contractor | Less than Meas. | Meas. 0 - 0.10 |
0.10 - 0.25 | 0.25 - 0.50 | 0.50 - 0.75 | 0.75 - 1.00 | 1 - 2 | 2 - 3 | 3 - 4 | 4 - 5 | >5 | Total Monitored | Percent of Monitored with Meas. TED | No. with Meas. TED | Collective TED (Person-rem) |
Avg. Meas. TED (rem) | ||||||
| ENRICHMENT | ||||||||||||||||||||||
| Bechtel Jacobs - Paducah | 109 | 31 | 140 | | | 22% | | | 31 | | | 0.231 | | | 0.007 | | | ||||||||||
| Totals | 109 | 31 | 140 | 22% | 31 | 0.231 | 0.007 | |||||||||||||||
| FABRICATION | ||||||||||||||||||||||
| PROCESSING | ||||||||||||||||||||||
| SRNS Construction | 46 | 26 | 7 | 3 | 82 | 44% | 36 | 2.387 | 0.066 | | | ||||||||||||
| Savannah River Nuclear Solutions | 495 | 219 | 10 | 724 | | | 32% | 229 | | | 8.383 | | | 0.037 | |||||||||||
| SRNS Service Subs | 51 | 4 | 55 | 7% | 4 | 0.114 | 0.029 | |||||||||||||||
| Misc. DOE Contractors - SR | 1 | 1 | 2 | 50% | 1 | 0.017 | 0.017 | |||||||||||||||
| Savannah River Field Office | 28 | 2 | 30 | 7% | 2 | 0.032 | 0.016 | |||||||||||||||
| SRNS Construction Subs | 3 | 3 | 100% | | | 3 | 0.035 | 0.012 | |||||||||||||||
| SRR Operations | 11 | 6 | 17 | 35% | 6 | 0.065 | 0.011 | |||||||||||||||
| Misc. S.R.S. Const. Subcontractors | 1 | 1 | 100% | | | 1 | 0.007 | 0.007 | |||||||||||||||
| Wackenhut Services Inc. - SR | 84 | 1 | 85 | 1% | 1 | 0.006 | 0.006 | |||||||||||||||
| DeNuke Services (SPRU-LA) | 75 | 75 | 0% | 0 | 0.000 | 0.000 | ||||||||||||||||
| Totals | 791 | 263 | 17 | 3 | 1,074 | 26% | 283 | 11.046 | 0.039 | |||||||||||||
| Note: Boxed values (gray background) indicate the greatest value in each column. | ||||||||||||||||||||||