^§ 835.1002  Facility design and modifications. 


§ 835.1003 Control procedures.
(a) During routine operations, the combination of design features and administrative control procedures shall provide that: (1) The anticipated magnitude of the total effective dose equivalent shall not exceed 5 rems (0.05 sievert) in a year; (2) The anticipated magnitude of the committed dose equivalent to any organ or tissue, plus any deep dose equivalent from external exposure, shall not exceed 50 rems (0.5 sievert) in a year; and (3) Exposure levels are as low as reasonably achievable. (b) Compliance with the requirements in paragraph (a) of this section shall be demonstrated by appropriate monitoring pursuant to the provisions of subpart E of this part.

vSubpart L-Releases of Materials and Equipment From Radiological Areas